Industrial IoT, built on the control system you already run

Plant data is useful only once somebody acts on it. We connect the controllers, instruments and drives already in your plant, then put the numbers where your team will actually look.

Our position

Most IIoT projects fail at the bottom, not the top

The dashboard is the easy part. What sinks these projects is the layer underneath: a tag that was never scaled, a drive that reports in the wrong units, a historian logging at a rate that hides the event you were looking for.

We come at IIoT from the control side. The same engineers who write the PLC logic and check the loops set up the data collection, which means the numbers on the dashboard mean what you think they mean.

We are not selling you a platform. If your plant already has one, we will connect to it. If it does not, we will tell you honestly whether you need one yet.

Data starts at the terminalConnectivity is a control problem before it is a software problem
What we deliver

Six things plants actually ask us for

Each one stands on its own. You do not need a plant-wide programme to start.

01

Plant connectivity

Getting data out of controllers, drives and instruments that were never specified to share it.

  • OPC UA and Modbus TCP gateways
  • Protocol conversion for legacy equipment
  • Edge devices at the panel
02

Historian & data collection

Logging at a rate and resolution that still answers the question six months later.

  • Tag selection and scan-rate design
  • Historian configuration and retention
  • Data integrity and gap handling
03

Dashboards & reporting

Screens built for a shift engineer, not for a boardroom slide nobody opens twice.

  • Production, availability and downtime views
  • Automated shift and daily reports
  • Role-based access for plant and management
04

Remote monitoring

Visibility of unmanned assets, and alarms that reach a person rather than a screen nobody is watching.

  • Telemetry from outstations and remote plant
  • Alarm dispatch to phone and email
  • Secure remote access for diagnostics
05

Condition-based maintenance

Using what the drives and instruments already report to catch failures in a service window.

  • Motor current, vibration and temperature trends
  • Runtime and duty-cycle tracking
  • Threshold alerts before a breakdown
06

Network segregation

Connecting the plant without exposing it. The control network stays a control network.

  • OT and IT network separation
  • One-way data paths where appropriate
  • Access control and change logging
How it fits together

Four layers, bottom up

Each layer only works if the one below it is right. We build from the field upwards, which is why we start by asking about your instruments rather than your dashboard.

Field PLC, drives, instruments Edge gateway & protocol Historian storage & context Dashboards people who act correct scaling & units loop integrity OPC UA / Modbus TCP OT / IT separation retention & scan rate
Field instrumentation Edge gateways OPC UA & Modbus TCP Historian Operational dashboards Network segregation
Worth saying plainly

Start with one question, not a platform

The IIoT projects that work start with a specific question somebody in the plant wants answered: why does line two lose an hour every Tuesday, which motor is drawing more than it did last quarter, how much steam does a grade change actually cost. Pick one, instrument it properly, and the business case for the next one writes itself. Projects that start with a platform purchase usually end with an unused licence.

Tell us your question
Where it pays back

Four places plants see it first

None of these need a new control system. They need the one you have to start reporting properly.

Downtime you can explain

Stoppage reasons captured automatically rather than written on a clipboard, so the Pareto chart in your morning meeting reflects what actually happened.

Motors that warn you

Current and temperature trends from drives you already own, surfaced early enough to replace a bearing in a service window instead of a shutdown.

Energy per unit produced

Consumption tied to output rather than to a monthly bill, which is the only form in which an energy number is actionable on the plant floor.

Is it for you?

When IIoT is worth doing, and when it is not

We would rather tell you to wait than sell you a project that sits unused. Here is roughly how we judge it on a first call.

Get an honest read
Signs you are ready
  • A specific question nobody can answer today
  • Instruments and drives already in place
  • Somebody who will own the numbers
  • A decision that would change with better data
  • IT and OT willing to agree on a network boundary
If your field instrumentation is unreliable, fix that first. Dashboards built on bad measurement are worse than no dashboard, because people trust them.
Start a conversation

What would you want the plant to tell you?

Send us one question you cannot answer today. We will tell you what it would take to answer it, and whether it is worth doing.

Chat with an engineer